High Clean Diaphragm Valve

Oerating Principles

Diapharagm valves, manually or pneumatically operated, are specifically designed for hygienic and aseptic processes in the pharmaceutical industries.
The valve is excellent for flow control as well as for open/close duties.
The diaphragm provides body seal as well as seat seal. There are no paths to outside environment so it is suitable for aseptic processes.
When valve is closed, a pressure pad which supports diaphragm move towards sealing face on body. When pressure plate moves, diaphragm flexes and is forced down onto seat area in the centre of body, thus it closes off flow path through body.
The interrelationship of body is to prevent the compression of diaphragm.
The valve can be manually/pneumatically operated, and can be controlled by control tops and solenoid valves.

Technical Specifications
Size: 1"-4", DN25-DN100
Pressure: 10bar (145PSI)
Material: ASTM 316L, 1.4404, 1.4435 NB2 Fe<0.5%
Temperature: -20 °C +150 °C (EPDM) -4 F +302 °F (+140 °C (SIP, 30) 284 °F)
Connection Type: Clamp, Weld, Thread, 3A BPE DIN SMS IDF ISO
Body Structure: straight, tee, U-tee, tank botoom valve, multi-channel diaphragm
Diaphragm Material: EPDM + PTFE (double layer) / EPDM/ Silicon/ FPM(Viton)
Certificate: 3A-54-02/ 1580, PED 97/23 EC, FDA177.2600